VENTILATION ARRANGEMENT FOR HAZARDOUS SPACES IN ENGINE ROOM

The following engine room spaces are very hazardous on-board the ship and therefore, a special ventilation arrangement should be provided for safe entry:

(a) CO2 storage compartment
(b) Battery room
(c) Purifier flat
(d) Refrigerating machinery space
(e) Shaft tunnel

Ventilation Arrangement for Confined Spaces of Ships:

(a) CO2 storage compartment
– CO 2 compartment is situated on open deck , well ventilated and easily accessible .
– Its compartment door is opened outward.
– Boundaries between CO2 compartment should be watertight.
– Ventilation louver is fitted at the bottom near the floor , for the leaky CO2 to release to atmosphere because CO2 is more heavier than normal air.
– In some ships , exhaust fan is provided . Its suction is taken from bottom of the compartment and lead to open air deck . Exhaust system is separately provided from others.
– In some modern built ships , CO2 leakage warning alarm is provided
(b) Battery room
– Battery room is provided good ventilation, to prevent accumulation of Hydrogen gas and risk of battery explosion
– In the room , batteries should not be placed on the floor . It must be put on the level racks.
– Ventilation inlets are arranged below the battery level.
– Ventilation outlets are arranged at the top of a battery compartment.
– If the vent is other than direct to the outside , an exhaust fan is required. The fan is in the air stream from the compartment.
– The exhaust fan must be independent from other ventilation systems.
– All ventilation ducts should be made with corrosion resistant material.
(c) Purifier Flat
– Purifier flat is usually located at the E/R bottom floor. In some ships , purifiers are provided with separate compartment.
– Normally purifiers are operating with heaters to obtain efficient purification. Therefore , inflammable gases and some leakage of heated oil are usually accumulated in the Purifier flat . By this reason purifier space or room is provided with an exhaust blower to achieve better ventilation. , in addition to the fresh air supplied by E/R ventilation
– Out let form the purifier room blower lead to the open deck . Its louver is fitted with cover , normally open , but to close in case of fire in engine room , for CO2 release .
– The exhaust blower can be stopped from emergency remote station outside engine room .
(d) Refrigerating machinery space
– Ventilation system for Refrigerating plant is depend upon the type of refrigerant used.
– In Freon Gas refrigeration system, normal E/R ventilation is sufficient for the refrigerating plant space. If the plant is provided with separate compartment normal ventilated louver is provided.
– But for Ammonia and CO2 refrigeration system ,being they are harmful to human life , positive
ventilation system i.e , exhaust fan must be used to repel any leakage of CO2 and NH3 gas to outside
atmosphere. This reduce the risk of danger for explosion or suffocation.
(e) Shaft Tunnel
– In shaft tunnel , natural draught fan is used. The force ventilation , supplied air for Engine Room is
passing through shaft tunnel via opened water tight door. The hot & foul air from shaft tunnel may
escape through emergency exit from shaft tunnel to open deck.
– In some ships , shaft tunnel ventilation is provided.

2 comments:

  1. Nice blog!
    If you’re thinking about Gas Fire Installation Glasgow but aren’t sure what it entails, read on and find out all about this increasingly popular heating solution!

    ReplyDelete
  2. Thanks for the information. I really like the way you express complex topics in lucid way. It really helps me understand it much better way. R407C refrigerant freon gas

    ReplyDelete

Meo class 2 written questions ( previous years)

MEO class 2 written questions.  previous yeas JAN 2016 - JULY 2017)